IMR 1400-compact
IMR 1400 – compact has been designed to measure flue gases
- Boiler
- Burner
- Engine
has been developed to meet
- the customers need and
- to fulfill special applications
is a high quality combustion
- gas analyzer using the
- latest sensor technology
is easy to use and will measure
- all the important parameters to adjust
- optimize the combustion process
Standard features
- Portable and very compact combustion gas analyzer housed in a rugged aluminum case
- Measurement of:
O2 Oxygen, CO Carbon Monoxide, TG Flue-gas temperature, NO Nitric oxide(14090/14190), SO2 (14091/14191) - ASME/BImSchV - Calculation:
Combustion efficiency,Losses,Excess Air, CO2 Carbon Dioxide - 7 Fuels are programmed – 5 fuels are programmable
- Automatic zero calibration
- Integrated self check program
- Simultaneous display of eight parameters on the illuminated display
- Unit selection : ppm - mg - mg(ref O2) – mg/kWh
- Gas sampling probe E – length 0.8 ft (250mm) , hose 8 ft (2.5m)
- Rechargeable battery
- Thermal printer (14100 / 14190 / 14191)
- Power supply 110VAC/60Hz or 230VAC/50Hz
Optional features
- Ambient air temperature probe
- NO-measurement (14090 / 14190)
- Gas sampling probe with heated handle
- SO2-measurement (14091 / 14191)
- Gas sampling probes with different lengths
- NO2-measurement
- Electronic controlled soot measurement
- HC-measurement
- RS 232 interface
- CO-bypass valve with purging pump
- Memory for 200 measurements
- 12V DC power jack
- Draft measurement
Technical data
PARAMETER | PRINCIPLE | RESOLUTION | ACCURACY | RANGE | STANDARD |
---|---|---|---|---|---|
O2 Oxygen | Electro-chemical | 0.1 Vol.% | ± 0.2 % | 0-20.9Vol.% | |
CO Carbon monoxide | Electro-chemical | 1 ppm | 5 % | 0-2,000ppm | |
COp Carbon monoxide-corrected | Calculation | 1 ppm | 5 % | ||
NO Nitric oxide | Electro-chemical | 1 ppm | 5 % | 0-,2000 ppm | 14090/14190 |
NO2 Nitric dioxide | Electro-chemical | 1 ppm | 5 % | 0- 100 ppm | |
SO2 Sulfur dioxide | Electro-chemical | 1 ppm | 5 % | 0-4,000 ppm | 14091/14191 |
HC Hydrocarbons | 0.1% | 5 % | 0-100% LEL | ||
TG Flue gas temperature | NiCr-Ni thermocouple | 1 K | ± 2 % | -4° F / 2192°F -20°C..1200°C |
|
TA Air temperature | Semiconductor | 1 K | ± 0.5 K | -4° F / 248° F -20°C..120°C |
|
P Draft | Solid state | 0.004" H2O 0.01 hPa |
± 2 % | -12" / 20" H2O -30hPa/+50hPa |
|
CO2 Carbon dioxide | Calculation | 0.1 Vol.% | ± 0.2 % | 0- CO2max | |
Efficiency / ETA | Calculation | 1 % | ± 0.5 % | 0-999 % | |
Losses / qA | Calculation | 1 % | ± 0.5 % | 0-999 % | |
Excess Air/LAMBDA | Calculation | 1 % | ± 2 % | 0-999 % | |
Soot | Filter paper method |
Other measurement ranges are available upon request
Equipped with max 4 sensors
SPECIFICATION
Dimensions wxdxh: | |
1400C: | 12"(305mm) x 9"(228mm) x 4.6"(116mm) |
1400C/P (printer): | 16"(425mm) x 7"(185mm) x 11" (290mm) |
Weight: | |
1400C: | approx. 6.7lbs. (2.9kg) |
1400C/P (printer): | approx. 15lbs. (5.8kg) |
MODEL | PART-NO. |
IMR 1400-c O2, CO | 14000 |
IMR 1400-c O2,CO, NO | 14090 |
IMR 1400-c O2,CO, SO2 | 14091 |
IMR 1400-cp O2,CO | 14100 |
IMR 1400-cp O2,CO, NO | 14190 |
IMR 1400-cp O2,CO, SO2 | 14191 |